1.
Chinese Journal of Radiological Medicine and Protection ; (12): 326-328, 2012.
Article in Chinese | WPRIM | ID: wpr-427083

ABSTRACT

Objective To study the image quality and radiation dose in dual-source CT cerebral angiography with prospective ECG-triggered sequence mode (step-and-shoot,SAS).Methods A total of forty-three patients with clinically suspected cerebral vascular disease underwent cerebral CT angiography with prospective ECG-triggering (step-and-shoot,SAS).Data acquisition was at 60% R-R interval of the ECG presentation mode.The post-processing included maximum intensity projection (MIP),multiplanar reformation (MPR) and volume rendering (VR).The CTA image quality,radiation dose and rates of excellent images were evaluated.Results The CTA image quality score was 4.72 ± 0.50 and 97.7% (42/43) patients had excellent CTA images.The average effective dose of SAS-CTA was (0.22 ± 0.01 )mSv,which was lower by 76.31% than that of DE-CTA.Conclusions Prospective ECG-triggering sequence could be used in cerebral angiography with a significant reduction in radiation dose and diagnostic image quality.

2.
Chinese Journal of Radiology ; (12): 481-485, 2011.
Article in Chinese | WPRIM | ID: wpr-415507

ABSTRACT

Objective To compare the quality and radiation doses of coronary artery angiography under the natural heart rate condition between Flash spiral heart mode and prospective electrocardiogramtriggering sequence mode using dual-source,in order to choose personalized low doses of coronary artery scanning mode.Methods Sixty patients who underwent coronary angiography(CTA)on a 128-slice,dualsource CT scanner were divided into 2 group i.e,group A(27cases)and group B(33 cases).Flash spiral heart scan mode was employed for group A.Inclusion criteria included:heart rate75 bpm),date acquisition was set at 30%-50%of the R-R interval. (3)At the arrhythmias,premature beat,fibrillation atrial,date acquisition was set at 20%-90%of the R-R interval.In both gronps,patients with a BMI≥25.0kg/m2 were examined with a tube voltage of 120 kV.while the other patients with a BMI<25.0 kg/m2 were examined with a tube voltage of 100 kV.The BMl was(24.6±1.0)kg/m2 in group A,while that was (24.6±0.9)kg/m2 in group B.In both groups,all images were transferred to the workstation for further processing and analysis.The imaging quality of coronary artery segments and the radiation dose were compared with t test.Results A total of 336 coronary artery segments were evaluated in group A and 412 segments were evaluated in group B.The imaging quality of coronary artery segments were scored.Excellent or good was achieved in 98.2%(330 of 336)artery segments in group A,and that was 98.1%(404 of 412)in group B.There was no statistical difference in imaging quality between the two groups(t=0.513,P=0.608).The average effective dose was(0.74±0.29)mSv in group A,whereas that was(3.67±1.37)mSv in group B.There was a significant difference between the two groups(t=-10.858,P=0.000).Conclusions The personalized low doses coronary artery scanning mode can substantially reduce radiation damage while preserving good imaging quality.

3.
Chinese Journal of Radiology ; (12): 281-284, 2008.
Article in Chinese | WPRIM | ID: wpr-401367

ABSTRACT

Objective To evaluate the diagnostic value of multi-slice spiral CT(MSCT)perfusion imaging in chronic obstructive pulmonary disease(COPD).Methods Twenty COPD patients and20 volunteers underwent 8-row detector spiral CT(MSCT)perfusion imaging using cine scan mode with5 mm slice thickness.0.5 s rotation time and a total scan time of 45 s with 5 s intervals.60 ml contrast agent(300 mg I/ml)were administered at a rate of 4 ml/s from the forearm superficial vein.The imaging data were transferred to a workstation.A time-density curve and pseudo-color map were generated automatically with GE CT perfusion 3 software,the blood flow(BF),blood volume(BV),mean transit time(MTr)and permeability surface(PS)were measured.Results Time-density curve was flatter and the peak of the curve was obviously lower in COPD patients than the volunteers.The BF.BV.PS in COPD volunteers was(10.58 ±4.85)s and(4.50 ±1.71)s respectively.The BF,BV and PS in COPD patients Was lower than the volunteers,the MTY was higher(P<0.01).Conclusion MSCT perfusion imaging is helpful for the diagnosis of COPD.